Title of article
Calibration of a solid state nuclear track detector (SSNTD) with high detection threshold to search for rare events in cosmic rays
Author/Authors
Dey، نويسنده , , S. and Gupta، نويسنده , , D. and Maulik، نويسنده , , A. and Raha، نويسنده , , Sibaji and Saha، نويسنده , , Swapan K. and Syam، نويسنده , , D. and Pakarinen، نويسنده , , J. and Voulot، نويسنده , , D. and Wenander، نويسنده , , F.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
4
From page
805
To page
808
Abstract
We have investigated a commercially available polymer for its suitability as a solid state nuclear track detector (SSNTD). We identified that polymer to be polyethylene terephthalate (PET) and found that it has a higher detection threshold compared to many other widely used SSNTDs which makes this detector particularly suitable for rare event search in cosmic rays as it eliminates the dominant low Z background. Systematic studies were carried out to determine its charge response which is essential before any new material can be used as an SSNTD. In this paper we describe the charge response of PET to 129Xe, 78Kr and 49Ti ions from the REX-ISOLDE facility at CERN, present the calibration curve for PET and characterize it as a nuclear track detector.
Journal title
Astroparticle Physics
Serial Year
2011