Title of article
Slope profile measurement of sewer inverts
Author/Authors
Dirksen، نويسنده , , J. and Pothof، نويسنده , , I.W.M. and Langeveld، نويسنده , , J.G. and Clemens، نويسنده , , F.H.L.R.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
9
From page
122
To page
130
Abstract
This paper presents the results of a study into the quality of the measurement of the slope profile of a sewer. Slope profile measurements can be used to assess the correct alignment of newly constructed sewers or the position of sewer pipes after differential settlement. For the measurement of the sewer invert profile a sewer inspection camera equipped with an electronic tilt meter can be used. The accuracy of the results of this measurement technique is not only determined by the specifications of the electronictilt meter but also by the execution of the measurement and properties of the measured object. To assess the influence of the latter two, the sewer invert profile one sewer was measured ten times. Analysis of the measurement results showed that the random errors are small and cancel out. Therefore differences in the slope of individual sewer pipes can be measured fairly accurately. The determination of the difference in level between either end of the sewer is inaccurate because of the systematic error.
Keywords
Sewer , Slope measurements , Differential settlement , uncertainty
Journal title
Automation in Construction
Serial Year
2014
Journal title
Automation in Construction
Record number
1338747
Link To Document