Title of article
Response of a thermoacoustic refrigerator to the variation of the driving frequency and loading
Author/Authors
Jebali، نويسنده , , Fathi and Lubiez، نويسنده , , Jean Valentin and François، نويسنده , , Maurice-Xavier، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
11
From page
165
To page
175
Abstract
The performance of a thermoacoustic refrigerator subjected to variable loading was analyzed experimentally and the data were compared with those obtained using a computational model. The computational model relies on one-dimensional cross-section-averaged equations discretized using the network analogy. The thermoacoustic refrigerator was modeled by dividing it into 1 mm long slices in the direction of the acoustic axis. The hot heat exchanger of the thermoacoustic refrigerator was maintained at ambient temperature and the temperature of the cold heat exchanger was varied to achieve temperature differences of ΔT=0, 5 and 10 K along the stack. The cooling load was measured and calculated for these temperature differences while varying the driving frequency between 30 and 65 Hz. The contribution of the progressive and stationary waves and the losses on the thermoacoustic heat flow was computed and discussed.
Keywords
Refrigeration , Modelling , Experimental , heat transfer , Refrigération , Thermoacoustique , Modélisation , Expérimentation , Transfert de chaleur , thermoacoustics
Journal title
International Journal of Refrigeration
Serial Year
2004
Journal title
International Journal of Refrigeration
Record number
1339661