• Title of article

    A new structural health monitoring system for composite laminates

  • Author/Authors

    B. Verijenko، نويسنده , , V. Verijenko، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    5
  • From page
    315
  • To page
    319
  • Abstract
    The increasing use of composite laminates in safety critical structures has prompted the development of a robust structural health monitoring system for laminates, which uses metastable ferrous alloy inserts embedded within the laminate during component construction to provide an indication of the peak tensile strain encountered by the laminate. The metastable ferrous alloy insert has an austenitic crystal structure at room temperature, but upon application of strain, this transforms to a thermodynamically stable martensite, resulting in a change in magnetic susceptibility, which can be correlated with the peak strain experienced by the material (strain memory effect). This paper presents the test results that show that it is possible to manufacture a smart laminate in this fashion, and that sufficient strain is experienced by the insert to provide a significant change in magnetic susceptibility, thereby warning of a high strain level in the laminate. Various insert geometries and laminate thicknesses are also tested for their effect on the susceptibility measurements.
  • Keywords
    Structural health monitoring , Strain memory , Composite laminates
  • Journal title
    COMPOSITE STRUCTURES
  • Serial Year
    2005
  • Journal title
    COMPOSITE STRUCTURES
  • Record number