Title of article
An experimental study on ice formation around horizontal long tubes
Author/Authors
Habeebullah، نويسنده , , Badr A. Habeebullah، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
9
From page
789
To page
797
Abstract
The results of an experimental study are presented where the growth rate of ice on the outside of cooled copper tubes was studied. The tubes, which were immersed in water in an insulated vessel, were internally cooled by circulating glycol through them.
found that axial growth rate of ice is distinct at low values of the coolant Reynolds number and short freezing times. The slope of the ice thickness with axial distance showed moderate dependency on time but varied with coolant flow rate, and with Stanton and Biot numbers.
result from the experiments is the abrupt ice thickness enlargements on the surface of tube bends. This anomaly may be attributed to internal flow disturbances of the coolant, and creation of local eddies inside the bends that enhance growth of ice. The effect was evident for a low Reynolds number (Re = 251.9 and Bi < 1), and fades out for large Reynolds number flows.
Keywords
Horizontal tube , Experiment , GROWTH , ICE , Accumulation thermique , Bac à glace , Cuivre , Tube horizontal , Glace , Expérimentation , Croissance , Thermal storage , Ice tank , Copper
Journal title
International Journal of Refrigeration
Serial Year
2007
Journal title
International Journal of Refrigeration
Record number
1341606
Link To Document