• Title of article

    Numerical analysis of the effect of helical nozzles gap on the cooling capacity of Ranque–Hilsch vortex tube

  • Author/Authors

    Pourmahmoud، نويسنده , , Nader and Hassanzadeh، نويسنده , , Amir and Moutaby، نويسنده , , Omid، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    11
  • From page
    1473
  • To page
    1483
  • Abstract
    In this article, the effect of helical nozzles on both energy separation and refrigeration phenomena in the Ranque–Hilsch Vortex Tube (RHVT) was investigated by CFD techniques. The radial gap of inlet of helical nozzle from the vortex chamber (GPL) stands as a significant designing parameter. The standard k–ɛ turbulence model was introduced to the governing equations for analyzing highly rotating complex flow field. The studied helical nozzles have the same profile shape but their radial distance from the chamber distinct them from each other. Presented numerical results show that operating the vortex tube with GPL = 0.034 leads to the maximum cooling effect and swirl velocity. Furthermore, by keeping GPL value constant, the effect of number of nozzles is studied in more detail. Present results in this article, show increasing of temperature separation due to increase of nozzle numbers, however the coefficient of performance (COP) does not change very significantly.
  • Keywords
    Energy separation , tuyères hélicoïdales , Simulation numérique , séparation dיénergie , vortex tube , Helical nozzles , Numerical simulation , Tube vortex
  • Journal title
    International Journal of Refrigeration
  • Serial Year
    2012
  • Journal title
    International Journal of Refrigeration
  • Record number