Quantitative risk assessment of R290 in ice cream cabinets
Author/Authors
Colbourne، نويسنده , , D. and Espersen، نويسنده , , L.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
12
From page
1208
To page
1219
Abstract
This study addresses the flammability risk of hydrocarbon (HC) refrigerants within horizontal type ice cream cabinets (ICC). Quantitative risk assessment (QRA) is used to estimate the likelihood of ignition of leaked refrigerant and severity of the consequences. Variables were evaluated including effect of room size, positioning of ICC, compressor compartment fan airflow and ignition source distribution. To strengthen the QRA, tests were carried out for refrigerant leakage and effects of ignition to validate dispersion and consequence models. Ignition frequency is between 1 × 10−8 and 2 × 10−13 per year. The maximum overpressure and thermal intensity within the room is 3 kPa and 200 s (kW m−2)4/3, respectively and 6.5 kPa and 20 s (kW m−2)4/3 from within the compressor compartment. The risks were found to be negligible compared to background and other reference values.
Keywords
analyse des risques , Inflammabilité , inflammation , Hydrocarbon , R290 , Propane , flammability , Risk analysis , Propane , R290 , Frigorigène , Refrigerant , Ignition , Hydrocarbure