• Title of article

    Characterization of dust collected from ASDEX-Upgrade and LHD

  • Author/Authors

    Sharpe، نويسنده , , J.Phillip and Rohde، نويسنده , , Volker and The ASDEX-Upgrade Experiment Team and Sagara، نويسنده , , Akio and Suzuki، نويسنده , , Hajime and Komori، نويسنده , , Akio and Motojima، نويسنده , , Osamu and The LHD Experimental Group، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    5
  • From page
    455
  • To page
    459
  • Abstract
    Dust has been collected and analyzed from Axial Symmetric Divertor Experiment-Upgrade (ASDEX-Upgrade) and the Large Helical Device (LHD). A total quantity of 984.4 mg of dust was collected from ASDEX-Upgrade, whereas only 17.6 mg was obtained from roughly equal sampling areas in LHD. Particle sizes determined by count-based measurements from all locations in ASDEX-Upgrade averaged 3.33 μm, and LHD dust had an average size of 9.64 μm. Dust from both devices was composed mainly of carbon and constituents of stainless steel, the materials used for most plasma-facing surfaces and the vacuum vessels. Specific surface area (SSA) of the dust from ASDEX-Upgrade ranged between 0.70 and 3.70 m2/g. LHD samples contained insufficient mass for measuring SSA. Details from the analysis of each dust collection activity in ASDEX-Upgrade and LHD are described in this paper.
  • Keywords
    Tokamak dust , Particulate , dust
  • Journal title
    Journal of Nuclear Materials
  • Serial Year
    2003
  • Journal title
    Journal of Nuclear Materials
  • Record number