Heinzel، نويسنده , , V and Bem، نويسنده , , P and Esposito، نويسنده , , E and Gordeev، نويسنده , , S and Fischer، نويسنده , , U and Moeslang، نويسنده , , A and Simakov، نويسنده , , S and Shimizu، نويسنده , , A and Sugimoto، نويسنده , , M and Tiseanu، نويسنده , , I and Vladimirov، نويسنده , , P and Watanabe، نويسنده , , Y and Yutani، نويسنده , , T، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
5
From page
223
To page
227
Abstract
The major components of the test cell are the three test modules, the shield plugs and the test cell covers. The existing drawings of the IFMIF test cell and the internals were put together to have a common basis for discussion. The high-flux-test-module was redesigned. The rigs were designed with a flat plate geometry. They are equipped with an electric heater system, with which the temperatures in the specimens stack can be kept at temperature levels between 250 and 650 °C within a tolerance of 30 °C. The temperature level of each rig can be adjusted independently. First result of the optimization of the medium-flux-test-module are also described.