• Title of article

    Mechanical properties of martensitic steels after exposure to flowing liquid metals

  • Author/Authors

    Aiello، نويسنده , , A. and Agostini، نويسنده , , M. and Benamati، نويسنده , , G. and Long، نويسنده , , B. and Scaddozzo، نويسنده , , G.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    5
  • From page
    217
  • To page
    221
  • Abstract
    This paper describes the tensile test results of martensitic steels EUROFER 97 and T91 after exposure to flowing Pb–17Li and Pb–55.5Bi alloy, respectively. The corrosion tests were performed in LIFUS II loop (Pb–17Li) and LECOR loop (Pb–55.5Bi) located in the ENEA Brasimone Center. Tensile test were carried in SYNTECH test machine under Ar atmosphere with an extension rate of 2 mm/min, and test temperature for EUROFER and T91 steels were at 480 and 400 °C respectively. The exposure of EUROFER steel to the liquid Pb–17Li did not affect its mechanical properties, while the ductility of T91 steel was deteriorated after exposed to flowing liquid Pb–55.5Bi.
  • Journal title
    Journal of Nuclear Materials
  • Serial Year
    2004
  • Journal title
    Journal of Nuclear Materials
  • Record number

    1361136