Title of article
Method of measuring depth profile of hydrogen in soda-lime glass
Author/Authors
Lenzen، نويسنده , , M. and Collins، نويسنده , , R.E. and Prince، نويسنده , , K.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
6
From page
317
To page
322
Abstract
The depth profile of hydrogen in glass, as an indicator for the presence of water, has been determined by two independent techniques. Secondary ion mass spectroscopy (SIMS) gives high spatial resolution measurements of the variation of hydrogen concentration as a function of depth into the glass. These measurements are not absolute, however. Elastic recoil detection analysis (ERDA) provides absolute measurements of the variation of hydrogen concentration with depth, although the spatial resolution is only in the order of 50 nm. The combination of the measurements obtained by these two techniques yields absolute high-resolution data of the depth dependence of hydrogen in glass.