Title of article
Conceptual design and analysis of a semi-passive containment cooling system for a large concrete containment
Author/Authors
Byun، C.S. نويسنده , , Jerng، D.W. نويسنده , , Todreas، N.E. نويسنده , , Driscoll، M.J. نويسنده ,
Issue Information
دوهفته نامه با شماره پیاپی سال 2000
Pages
-226
From page
227
To page
0
Abstract
An internal evaporator-only (IEO) concept has been developed as a semi-passive containment cooling system for a large dry concrete containment. The function of this system is to keep the containment integrity by maintaining the internal pressure not to exceed ultimate design pressure, i.e. 0.83 MPa (120 psia) in the absence of any other containment cooling following a severe accident, which postulates core damage and hydrogen combustion. The ability of the concept to protect the containment was evaluated for the design basis accident (DBA) large break loss of coolant accident (LB LOCA) and severe accident scenarios (LB LOCA without Emergency Core Cooling System (ECCS) and containment spray flow, 100% zirconium oxidation and complete hydrogen combustion). All were modeled using the GOTHIC computer code. It was concluded that a practical system requiring four IEO loops could be utilized to meet design criteria for severe accident scenarios.
Keywords
Hydrogen management , Overpressure protection , Boiling water reactors
Journal title
Nuclear Engineering and Design
Serial Year
2000
Journal title
Nuclear Engineering and Design
Record number
13814