• Title of article

    Investigations of the effect of electrode gap on the performance of a corona charger having separated corona and charging zones

  • Author/Authors

    Domat، نويسنده , , M. and Kruis، نويسنده , , F.E. and Fernandez-Diaz، نويسنده , , J.M.، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2014
  • Pages
    13
  • From page
    1
  • To page
    13
  • Abstract
    An efficient and a versatile unipolar corona charger was developed. It has indirect charging characteristics, with corona and charging regions separated. Ions were generated by a needle electrode and then driven to the charging region by a sheath flow in order to reduce the electrostatic loss of nanoparticles. The distance of the electrode to the walls can be adjusted by a micrometer, modifying the onset voltage and N i t - product , and therefore the intrinsic and extrinsic charging efficiencies and loss of charged particles. Experimental results indicate that the generated ion current is practically the same independent of the variation in the applied voltage or corona current, but varying the electrode gap distance seems to be a much more efficient way to regulate the N i t - product . The charging efficiency can vary from high values, comparable to the higher efficiency chargers presented in the literature, to lower levels such as reached with bipolar chargers.
  • Keywords
    Unipolar charger , Corona charger , N i t - product , Charging efficiency
  • Journal title
    Journal of Aerosol Science
  • Serial Year
    2014
  • Journal title
    Journal of Aerosol Science
  • Record number

    1386415