Title of article
Poroviscoelastic finite element model including continuous fiber distribution for the simulation of nanoindentation tests on articular cartilage
Author/Authors
Silvia Taffetani، نويسنده , , M. and Griebel، نويسنده , , M. and Gastaldi، نويسنده , , D. and Klisch، نويسنده , , S.M. and Vena، نويسنده , , P.، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2014
Pages
14
From page
17
To page
30
Abstract
Articular cartilage is a soft hydrated tissue that facilitates proper load transfer in diarthroidal joints. The mechanical properties of articular cartilage derive from its structural and hierarchical organization that, at the micrometric length scale, encompasses three main components: a network of insoluble collagen fibrils, negatively charged macromolecules and a porous extracellular matrix. In this work, a constituent-based constitutive model for the simulation of nanoindentation tests on articular cartilage is presented: it accounts for the multi-constituent, non-linear, porous, and viscous aspects of articular cartilage mechanics. In order to reproduce the articular cartilage response under different loading conditions, the model considers a continuous distribution of collagen fibril orientation, swelling, and depth-dependent mechanical properties. The modelʹs parameters are obtained by fitting published experimental data for the time-dependent response in a stress relaxation unconfined compression test on adult bovine articular cartilage. Then, model validation is obtained by simulating three independent experimental tests: (i) the time-dependent response in a stress relaxation confined compression test, (ii) the drained response of a flat punch indentation test and (iii) the depth-dependence of effective Poissonʹs ratio in a unconfined compression test.
y, the validated constitutive model has been used to simulate multiload spherical nanoindentation creep tests. Upon accounting for strain-dependent tissue permeability and intrinsic viscoelastic properties of the collagen network, the model accurately fits the drained and undrained curves and time-dependent creep response. The results show that depth-dependent tissue properties and glycosaminoglycan-induced tissue swelling should be accounted for when simulating indentation experiments.
Keywords
Nanoindentation , Constitutive model , Poroelasticity , Viscoelasticity , Articular cartilage
Journal title
Journal of the Mechanical Behavior of Biomedical Materials
Serial Year
2014
Journal title
Journal of the Mechanical Behavior of Biomedical Materials
Record number
1406441
Link To Document