• Title of article

    Planar laser-induced fluorescence (PLIF) measurements of liquid film thickness in annular flow. Part I: Methods and data

  • Author/Authors

    Schubring، نويسنده , , D. and Ashwood، نويسنده , , A.C. and Shedd، نويسنده , , T.A. and Hurlburt، نويسنده , , E.T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    10
  • From page
    815
  • To page
    824
  • Abstract
    Most approaches to the modeling of annular flow require information regarding the thin liquid film surrounding the central gas core. This film is hypothesized to present a rough surface to the gas core, enhancing interfacial shear and pressure loss, with the roughness closely linked to the height of the film. This height is typically obtained from conductance probe measurements. The present work used planar laser-induced fluorescence to provide direct visualization of the liquid film in upward vertical air–water annular flow. Images were processed to produce the distribution of film heights. The standard deviation and average film thickness are found to be an increasing function of liquid flow and a decreasing function of gas flow, with the standard deviation approaching 0.4 times the average at sufficient liquid flow.
  • Keywords
    Film Thickness , Annular flow , vertical flow , fluorescence