• Title of article

    Experimental study of inverted annular film boiling in a vertical tube cooled by R-134a

  • Author/Authors

    Nakla، نويسنده , , Meamer El and Groeneveld، نويسنده , , D.C. and Cheng، نويسنده , , S.C.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    9
  • From page
    67
  • To page
    75
  • Abstract
    An experimental investigation of inverted annular film boiling heat transfer has been performed for vertical up-flow in a round tube. The experiments used R-134a coolant and covered a pressure range of 640–2390 kPa (water equivalent range: 4000–14,000 kPa) and a mass flux range of 500–4000 kg m−2 s−1 (water equivalent range: 700–5700 kg m−2 s−1). The inlet qualities of the tests ranged from −0.75 to −0.03. The hot-patch technique was used to obtain the subcooled film boiling measurements. It was found that the heat transfer vs. quality curve can be divided into four different regions, each characterized by a different mechanisms and trends. These regions are dependent on pressure, mass flux and local quality. A detailed examination of the parametric trends of the heat transfer coefficient with respect to mass flux, inlet quality, heat flux and pressure was performed; reasonably good agreement between observed trends and those reported in the literature were noted.
  • Keywords
    Inverted annular film boiling , Hot-patch techniques
  • Journal title
    International Journal of Multiphase Flow
  • Serial Year
    2011
  • Journal title
    International Journal of Multiphase Flow
  • Record number

    1410485