• Title of article

    Investigation of RCF failure prewarning of Fe-based coating by online monitoring

  • Author/Authors

    Zhong-yu، نويسنده , , Piao and Bin-Shi، نويسنده , , Xu and Hai-Dou، نويسنده , , Wang and Dong-hui، نويسنده , , Wen، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2014
  • Pages
    5
  • From page
    156
  • To page
    160
  • Abstract
    Rolling contact fatigue (RCF) tests of plasma sprayed Fe-based coatings were conducted on a ball-on-disc tester. Acoustic emission (AE) technique was used to monitor the whole process of RCF test. The status of AE signals was used as a criterion to calculate the prewarning lifetime. Typical AE response signals for RCF fractures were extracted and the prewarning mechanism was investigated. Results showed that the prewarning lifetime is obviously shorter than RCF failure lifetime. This indicates that AE sensor accurately gives an early alarm before the occurrence of failure. The difference of the prewarning initial lead was due to the different failure mechanism.
  • Keywords
    rolling contact fatigue , Prewarning , Acoustic emission technique , Fe-based coating
  • Journal title
    Tribology International
  • Serial Year
    2014
  • Journal title
    Tribology International
  • Record number