Title of article
Fiber optic hydrogen detectors containing Mg-based metal hydrides
Author/Authors
Slaman، نويسنده , , M. and Dam، نويسنده , , B. and Pasturel، نويسنده , , M. and Borsa، نويسنده , , D.M. and Schreuders، نويسنده , , H. and Rector، نويسنده , , J.H. and Griessen، نويسنده , , R.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
8
From page
538
To page
545
Abstract
We report on the implementation of Pd-capped chemo-chromic metal hydrides as a sensing layer in fiber optic hydrogen detectors. Due to the change in optical properties of Mg-based alloys on hydrogen absorption, a drop in reflectance by a factor of 10 is demonstrated at hydrogen levels down to 15% of the lower explosion limit. The switching takes place in only a few seconds. Comparing Mg–Ni and Mg–Ti based alloys, we find that the latter has superior optical and switching properties. Using a 50 nm thick Mg70Ti30 film capped with a 30 nm Pd catalytic layer as the sensing layer, we report on the sensitivity of the fiber optic detector for hydrogen both in argon and oxygen, the temperature behavior and the reversibility.
Keywords
metal hydride , Switchable mirror , Absorbing light , Mg–Ti , Fiber optic hydrogen detector , Mg–Ni
Journal title
Sensors and Actuators B: Chemical
Serial Year
2007
Journal title
Sensors and Actuators B: Chemical
Record number
1438869
Link To Document