Abstract
This paper describes an optical sensor for the monitoring of ammonia gas. An open path optical technique is used to analyze the absorption lines of ammonia within the ultra-violet region. The optical sensor shows absorption lines comparable to the theoretical ammonia spectra. Cross-sensitivity with carbon dioxide and oxygen gas has been tested and clearly shows that these two gases have no effect on ammonia measurement in the ultra-violet region, between 200 nm and 230 nm. The optical sensor is able to detect ammonia down to 9 ppm with an average error less than 2%. The optical sensor system also shows a fast response time which is less than 4 s.