• Title of article

    Resonant cantilever sensors operated in a high-Q in-plane mode for real-time bio/chemical detection in liquids

  • Author/Authors

    Tao، نويسنده , , Yihan and Li، نويسنده , , Xinxin and Xu، نويسنده , , Tiegang and Yu، نويسنده , , Haitao and Xu، نويسنده , , Pengcheng and Xiong، نويسنده , , Bin and Wei، نويسنده , , Changzheng، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    9
  • From page
    606
  • To page
    614
  • Abstract
    A high quality-factor (Q-factor) in-plane-mode resonant cantilever sensor is developed for real-time bio/chemical detection in liquids. With electrothermal excitation and piezoresistive frequency read-out integrated, the proposed sensor is realized by micromachining technology. The in-plane mode cantilever resonator can substantially decrease the liquid drag force, comparing to conventional out-of-plane resonance-mode cantilever, thereby, having achieved a much higher Q-factor of 249 when the cantilever is connected with a phase-lock-loop (PLL) interface circuit in water. After the mass sensitivity is calibrated by specifically binding streptavidin-labeled Dynabeads with the biotin-immobilized cantilever in phosphate buffered saline (PBS) solution, specific-antibody immobilized cantilevers have been used in real-time detection of Escherichia coli in PBS solution. Real-time detection of Hg2+ ions in aqueous Hg(NO3)2 is also carried out by using sensing-group-modified cantilevers, resulting in a finer noise-limited resolution than 100 ppb.
  • Keywords
    Quality factor , In-plane resonance mode , E. coli , Detection in liquids , Microcantilever sensors , Hg2+ ions in water
  • Journal title
    Sensors and Actuators B: Chemical
  • Serial Year
    2011
  • Journal title
    Sensors and Actuators B: Chemical
  • Record number

    1439843