• Title of article

    Vacuum encapsulated resonators for humidity measurement

  • Author/Authors

    Hennessy، نويسنده , , Robert G. and Shulaker، نويسنده , , Max M. and Messana، نويسنده , , Matt and Graham، نويسنده , , Andrew B. and Klejwa، نويسنده , , Nathan and Provine، نويسنده , , J. and Kenny، نويسنده , , Tom W. and Howe، نويسنده , , Roger T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    7
  • From page
    575
  • To page
    581
  • Abstract
    This study uses surface resistance of silicon dioxide and a charge-biased, microshell encapsulated, single-anchored double-ended tuning fork resonator (DETF) to measure relative humidity (RH). As relative humidity increases, the surface resistance of silicon dioxide decreases due to increasing amounts of water adsorbed on the surface. This decrease in surface resistance leads to a faster charge decay from a capacitor. The DETF resonator converts the amount of charge on the capacitor to a frequency shift, via the electrostatic spring softening term. This frequency shift can be characterized by either exponential fitting or slope fitting. The hysteresis was shown to be less than 0.15% RH. The relative humidity is determined from the slope or the decay time constant, with the precision of 1.3 × 10−3% RH for slope fitting and 1.3 × 10−4% RH for exponential fitting.
  • Keywords
    Double ended tuning fork sensor (DETF) , Charge-bias , Surface conduction , Humidity sensor , Encapsulation
  • Journal title
    Sensors and Actuators B: Chemical
  • Serial Year
    2013
  • Journal title
    Sensors and Actuators B: Chemical
  • Record number

    1442531