Title of article
Long-term stability of a MEIS low energy hydrogen sensor
Author/Authors
Lang، نويسنده , , Michael J. Banach، نويسنده , , Ulrich and Nِrthemann، نويسنده , , Kai and Gerlitzke، نويسنده , , Anne-Kathrin and Milstrey، نويسنده , , Michael and Kaufer، نويسنده , , Raig and Woratz، نويسنده , , Michael and Hübert، نويسنده , , Thomas E. Moritz، نويسنده , , Werner، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
6
From page
395
To page
400
Abstract
A hydrogen sensor based on a silicon Metal/Solid Electrolyte/Insulator/Semiconductor (MEIS) structure with thin layers of the super-ionic conductor LaF3 and Pd gate metal was investigated in a hybrid structure on a resistance heater mounted on a ceramic substrate. The sensor was operated at room temperature, however, a short heating impulse once a day ensures a fast and reproducible dynamic behavior. The sensor was characterized in the concentration range typical for alarm levels up to 40% of the lower flammability limit and shows a logarithmic dependency of the sensor signal from the hydrogen concentration and a mean sensitivity of about 140 mV/decade. The response time (t90) is about 8 s. In a long term test for a period of three month, the sensor was exposed to hydrogen every two weeks. The sensor signal was shown to be stable in dynamic behavior, sensitivity and signal difference.
Keywords
Hydrogen detection , Long-term measurement , Low energy sensor , MEIS-structure
Journal title
Sensors and Actuators B: Chemical
Serial Year
2013
Journal title
Sensors and Actuators B: Chemical
Record number
1442874
Link To Document