• Title of article

    SECM characterization of immobilised enzymes by self-assembled monolayers on titanium dioxide surfaces

  • Author/Authors

    Oliveira، نويسنده , , E.M. and Beyer، نويسنده , , S. and Heinze، نويسنده , , J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    186
  • To page
    191
  • Abstract
    SECM in generator-collector mode was used to detect the presence of immobilised enzymes on titanium dioxide layers which were chemically or electrochemically generated with possible application as chemical sensors and biosensors. Glucose oxidase (GOx) and horseradish peroxidase (HRP) were immobilised by SAM generation using aminopropyltriethoxysilane (APTES) and ascorbic acid. The enzymes were successfully immobilised on two different TiO2 surfaces. A simple test of durability of the system was made and a model of SAM organisation is presented.
  • Keywords
    SECM , Titanium dioxide , Self-assembled monolayers , Enzyme
  • Journal title
    Bioelectrochemistry
  • Serial Year
    2007
  • Journal title
    Bioelectrochemistry
  • Record number