Title of article
Low-Frequency EPR Detection of Chromium(V) Formation by Chromium(VI) Reduction in Whole Live Mice
Author/Authors
Liu، نويسنده , , K.J. and Jiang، نويسنده , , J.J. and Swartz، نويسنده , , H.M. and Shi، نويسنده , , X.G.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1994
Pages
5
From page
248
To page
252
Abstract
Measurements by direct low frequency EPR spectroscopy provide the first evidence that Cr(V) is generated in one-electron. reduction of Cr(VI) in live mice. The Cr(V) yield reached a maximum about 10 min following Cr(VI) intravenous injection and then decayed slowly with a life time of approximately 37 min. The time for the Cr(V) EPR signal to reach maximum intensity increased with the dose of Cr(VI). A discernible EPR signal was still observable at a dose as low as 0.1 mmol/kg. The Cr(V) was found predominantly in the liver, with a small amount in the blood. No Cr(V) signal was detectable in heart, spleen, kidney, and lung. Pretreatment of the animals with metal ion chelators, ethylenediaminetetraacetic acid, diethylenetriaminepentaacetic acid, and 1,10-phenanthroline significantly reduced the intensity of the Cr(V) signal that was observed.
Journal title
Archives of Biochemistry and Biophysics
Serial Year
1994
Journal title
Archives of Biochemistry and Biophysics
Record number
1452318
Link To Document