• Title of article

    Doolittle multivariate calibration algorithm and analysis of W, Mo, Ti–SAF system

  • Author/Authors

    Ding، نويسنده , , Yaping and Mu، نويسنده , , Ting and Wu، نويسنده , , Qingsheng and Si، نويسنده , , Shenzhu، نويسنده ,

  • Issue Information
    دوفصلنامه با شماره پیاپی سال 2007
  • Pages
    3
  • From page
    167
  • To page
    169
  • Abstract
    Being an accurate and stable algorithm, Doolittle Decomposition Algorithm (DDA) was first introduced into the chemistry field. The basic principle of Doolittle Multivariate Calibration Algorithm (DMCA) was investigated, and the chromogenic system of W, Mo, Ti–SAF with overlapping absorption peaks was analyzed by DMCA. The computational relative standard deviation with DMCA is within ± 8.0% which was better than the result of K-Matrix (within ± 10.0%), the comparison indicated the superiority of Doolittle Decomposition Algorithm in the concentration analyzing. It was demonstrated that DDA can avoid matrix inverting, reduce the orders of matrixes and speed up the operation of matrixes. So it has bright prospects in chemometrics.
  • Keywords
    Doolittle Decomposition Algorithm , Multivariate calibration , W , MO , TI
  • Journal title
    Chemometrics and Intelligent Laboratory Systems
  • Serial Year
    2007
  • Journal title
    Chemometrics and Intelligent Laboratory Systems
  • Record number