• Title of article

    Validation of a rapid micellar electrokinetic capillary chromatographic method for the simultaneous determination of isoniazid and pyridoxine hydrochloride in pharmaceutical formulation

  • Author/Authors

    Nemutlu، نويسنده , , E. and Celebier، نويسنده , , M. Umit Uyar، نويسنده , , B. and Alt?n?z، نويسنده , , S.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    8
  • From page
    35
  • To page
    42
  • Abstract
    An efficient and reliable micellar electrokinetic capillary chromatography (MEKC) method has been developed for the simultaneous determination of isoniazid (ISO) and pyridoxine hydrochloride (PYR) in pharmaceutical formulations. A chemometric two level full factorial design approach was used to search for the optimum conditions of separation. Three parameters were selected for this study: the buffer pH, the buffer concentration and sodium dodecyl sulphate (SDS) concentrations. Resolution, peak symmetry and analysis time were established as response. The two analytes were separated within 6 min with the optimized conditions: 50 mM borate buffer, 25 mM SDS pH 7.8, 35 °C, at 50 mbar 4 s injection and 30 kV by using a fused silica capillary (72 cm effective length, 50 μm i.d.). The detection wavelength was set to 205 nm. Meloxicam was used as internal standard. The method was validated with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity and robustness. The detection limits of the method were 1.0 μg mL−1 for ISO and 0.40 μg mL−1 for PYR and the method was linear at least in the range of 3.0–100 μg mL−1 for ISO and 1.0–100 μg mL−1 for PYR with excellent correlation coefficients (0.9995 for ISO and 0.9998 for PYR). Relative standard deviations (R.S.D.s) of the described method ranged between 0.54 and 2.27% for intra-day precision and between 0.65 and 2.69% for inter-day precision. The developed method was applied to the tablet form of ISO and PYR-containing the pharmaceutical preparations and the data were compared with obtained from the standard addition method. No statistically significant difference was found.
  • Keywords
    Experimental design , pharmaceutical , Pyridoxine hydrochloride , Micellar electrokinetic capillary chromatography (MEKC) , Isoniazid , Validation
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2007
  • Journal title
    Journal of Chromatography B
  • Record number

    1464771