• Title of article

    A simple HPLC method for the determination of bifendate: Application to a pharmacokinetic study of bifendate liposome

  • Author/Authors

    Chen، نويسنده , , Zhi-Peng and Zhu، نويسنده , , Jia-Bi and Chen، نويسنده , , Hong-Xuan and Xiao، نويسنده , , Yan-Yu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    246
  • To page
    250
  • Abstract
    A rapid, sensitive and simple high-performance liquid chromatographic (HPLC) method with ultraviolet detector (UV) has been developed for the determination of bifendate in 100 μl plasma of rats. Sample preparation was carried out by deproteinization with 100 μl of acetonitrile. A 20 μl of supernatant was directly injected into the HPLC system with methanol–double distilled water (65/35, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Separation was performed with a μBondapak C18 column at 30 °C. The peak was detected at 278 nm. The calibration curve was linear (r2 = 0.9989) in the concentration range of 0.028–2.80 μg/ml in plasma. The intra- and inter-day variation coefficients were not more than 6.55% and 6.07%, respectively. The limit of detection was 5 ng/ml. The mean recoveries of bifendate were ranged from 94.53% to 99.36% in plasma. The present method has been successfully applied to the pharmacokinetic study of bifendate liposome in rats.
  • Keywords
    Bifendate
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2007
  • Journal title
    Journal of Chromatography B
  • Record number

    1465169