Title of article
Optimization of oxidative desulfurization of thiophene using Cu/titanium silicate-1 by box-behnken design
Author/Authors
Jose، نويسنده , , N. and Sengupta، نويسنده , , S. and Basu، نويسنده , , J.K.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
7
From page
626
To page
632
Abstract
The oxidative desulfurization of thiophene in a synthetic mixture of thiophene and iso-octane was investigated with copper loaded titanium silicate-1 (TS-1) catalyst in presence of hydrogen peroxide as oxidising agent and the conversion was enhanced by 22% at 240 min on addition of 1.05 wt.% copper in TS-1. The optimal design of experiments using box-behnken method was employed to evaluate the effects of individual process variables such as, reaction temperature, amount of catalyst and moles of hydrogen peroxide per mole of thiophene and their optimum values were found to be 70 °C, 0.45 g (22.5 mol/L of iso-octane) and 19.9 mol (in 20 ml of iso-octane), respectively, to achieve a conversion of 93%. The influence of mass transfer effects on the desulfurization reaction was minimized by selecting proper degree of agitation and catalyst size. An empirical kinetic model was used to interpret the rate data. The apparent activation energy was found to be 28.67 kJ/mol.
Keywords
Box-Behnken design , Thiophene , Desulfurization , Kinetic study
Journal title
Fuel
Serial Year
2011
Journal title
Fuel
Record number
1466424
Link To Document