Abstract
An analytical method was developed for the simultaneous speciation of selenomethionine (SeMet) and 2-hydroxy-4-methylselenobutanoic acid (NutraSelen®), a new SeMet precursor. The compounds could be baseline resolved by ion-pairing reversed-phase HPLC using ICP MS detection. Detection limits of 1 ng mL−1 (Se content) could be reached. SELM-1 reference material was used to validate the SeMet measurement. Additionally, the quantification of NutraSelen® was validated by standard addition together with checking the Se mass balance. The procedure developed was then applied to the monitoring of the conversion of NutraSelen® into SeMet by yeast.
Keywords
selenomethionine , NutraSelen® , HPLC–ICP MS , Selenium