• Title of article

    Simultaneous determination of asymmetric and symmetric dimethylarginine, l-monomethylarginine, l-arginine, and l-homoarginine in biological samples using stable isotope dilution liquid chromatography tandem mass spectrometry

  • Author/Authors

    Davids، نويسنده , , Mariska and Swieringa، نويسنده , , Eliane and Palm، نويسنده , , Fredrik and Smith، نويسنده , , Desirée E.C. and Smulders، نويسنده , , Yvo M. and Scheffer، نويسنده , , Peter G. and Blom، نويسنده , , Henk J. and Teerlink، نويسنده , , Tom، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    10
  • From page
    38
  • To page
    47
  • Abstract
    Production of the endogenous vasodilator nitric oxide (NO) from l-arginine by NO synthase is modulated by l-homoarginine, l-monomethylargine (MMA), asymmetric dimethylarginine (ADMA) and symmetric dimethylarginine (SDMA). Here we report on a stable isotope dilution liquid chromatography tandem mass spectrometry (LC–MS/MS) method for simultaneous determination of these metabolites in plasma, cells and tissues. After addition of the internal standards (D7-ADMA, D4-l-homoarginine and 13C6-l-arginine), analytes were extracted from the samples using Waters Oasis MCX solid phase extraction cartridges. Butylated analytes were separated isocratically on a Waters XTerra MS C18 column (3.5 μm, 3.9 mm × 100 mm) using 600 mg/L ammonium formate in water - acetonitrile (95.5:4.5, v/v) containing 0.1 vol% formic acid, and subsequently measured on an AB Sciex API 3000 triple quadrupole mass spectrometer. Multiple reaction monitoring in positive mode was used for analyte quantification. Validation was performed in plasma. Calibration lines were linear (r2 ≥ 0.9979) and lower limits of quantification in plasma were 0.4 nM for ADMA and SDMA and 0.8 nM for the other analytes. Accuracy (% bias) was <3% except for MMA (<7%), intra-assay precision (expressed as CV) was <3.5%, inter-assay precision <9.6%, and recovery 92.9–103.2% for all analytes. The method showed good correlation (r2 ≥ 0.9125) with our previously validated HPLC-fluorescence method for measurement in plasma, and was implemented with good performance for measurement of tissue samples. Application of the method revealed the remarkably fast (i.e. within 60 min) appearance in plasma of stable isotope-labeled ADMA, SDMA, and MMA during infusion of D3-methyl-1-13C-methionine in healthy volunteers.
  • Keywords
    Asymmetric dimethylarginine , Liquid chromatography tandem mass spectrometry , Nitric oxide , l-Monomethylarginine , Symmetric dimethylarginine , l-Homoarginine
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2012
  • Journal title
    Journal of Chromatography B
  • Record number

    1470056