• Title of article

    Development of a novel device for applying uniform doses of electron beam irradiation on carcasses

  • Author/Authors

    Maxim، نويسنده , , Joseph E. and Neal، نويسنده , , Jack A. and Castillo، نويسنده , , Alejandro، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    6
  • From page
    373
  • To page
    378
  • Abstract
    The Maximʹs Electron Scatter Chamber (Maxim Chamber) was developed to obtain uniform dose distribution when applying electron beam (e-beam) irradiation to materials of irregular surface. This was achieved by placing a stainless steel mesh surrounding a cylindrical area where the target sample was placed. Upon contact with the mesh, electrons scatter and are directed onto the target from multiple angles, eliminating the e-beam linearity and resulting in a uniform dose distribution over the target surface. The effect of irradiation in the Maxim Chamber on dose distribution and pathogen reduction was tested on rabbit carcasses to simulate other larger carcasses. The dose uniformity ratio (DUR) on the rabbit carcasses was 1.8, indicating an acceptable dose distribution. On inoculated carcasses, this treatment reduced Escherichia coli O157:H7 by > 5 log cycles. These results indicate that carcass irradiation using e-beam is feasible using the Maximʹs electron scattering chamber. Appropriate adjustments will be further needed for commercial application on beef and other animal carcasses.
  • Keywords
    pathogen reduction , E. coli O157:H7 , Maxim Chamber , Electron scattering , electron beam irradiation , Carcass interventions
  • Journal title
    Meat Science
  • Serial Year
    2014
  • Journal title
    Meat Science
  • Record number

    1491279