Title of article
An experimental investigation on the lateral behavior of knee-braced cold-formed steel shear walls
Author/Authors
Zeynalian، نويسنده , , Mehran and Ronagh، نويسنده , , H.R.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
12
From page
64
To page
75
Abstract
Experimental investigations were conducted to evaluate the lateral seismic characteristics of light-weight knee-braced cold-formed steel structures. In all, four full-scale 2.4×2.4 m2 specimens with different configurations were tested under a standard cyclic loading regime. This paper focuses on the specimensʹ maximum lateral load capacity and deformation behavior and provides a rational estimate of the seismic response modification factor, R, of knee-braced walls. The study also looks at the failure modes of the system and investigates the main factors contributing to the ductile response of CFS walls. That is in order to suggest improvements so that the shear steel walls respond plastically with a significant drift and without any risk of brittle failure, such as connection failure or stud buckling. A discussion on the calculated response factors in comparison to those suggested in the relevant codes of practice is also presented.
Keywords
Light steel frames , Knee-braces , Lateral performance , cold-formed steel , Response modification factor
Journal title
Thin-Walled Structures
Serial Year
2012
Journal title
Thin-Walled Structures
Record number
1493369
Link To Document