• Title of article

    Fire safety analysis of a 3D frame structure based on a full-scale fire test

  • Author/Authors

    Pyl، نويسنده , , Lincy and Schueremans، نويسنده , , Luc and Dierckx، نويسنده , , Willem and Georgieva، نويسنده , , Iveta، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    9
  • From page
    204
  • To page
    212
  • Abstract
    The topic of this paper is the fire safety analysis of 3D frame structures such as industrial halls. Cold-formed thin plated elements are used as structural components. The building, which is submitted to a full-scale fire test, is introduced. A blind prediction analysis is performed using the finite element model SAFIR. The thermal response of the structural elements under both a standard fire and a natural fire corresponding to a fire load density of 625 MJ/m2 and an opening factor 0.009 m1/2 is predicted. As expected, the temperature of the cold-formed sections follows more or less the gas temperature in the fire compartment due to the thin plates. The results of the predicted mechanical response are presented, giving a resistance of 27 min (standard fire) and 54 min (natural fire). The model is validated based on the results of the full-scale fire test, demonstrating a fire resistance of 62 min. Comparison with a simple 2.5D model is made and proved to provide results sufficiently accurate to make it applicable for daily design practice.
  • Keywords
    Fire Resistance , 3D-frame , Full-scale fire test , Numerical model , Validation
  • Journal title
    Thin-Walled Structures
  • Serial Year
    2012
  • Journal title
    Thin-Walled Structures
  • Record number

    1493656