• Title of article

    Analysis of eleven iridoid glycosides by micellar electrokinetic capillary chromatography (MECC) and screening of plant samples by partial filling (MECC)–electrospray ionisation mass spectrometry

  • Author/Authors

    Suomi، نويسنده , , Johanna and Wiedmer، نويسنده , , Susanne K and Jussila، نويسنده , , Matti and Riekkola، نويسنده , , Marja-Liisa، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    10
  • From page
    287
  • To page
    296
  • Abstract
    Of ammonium, lithium and sodium salts of dodecyl sulfate studied as surfactants in the separation of iridoid glycosides by micellar electrokinetic capillary chromatography (MECC), the last one gave the best results. Eleven neutral iridoid glycosides were separated by MECC with sodium dodecyl sulfate as surfactant, and the water–micelle partition coefficients of the compounds were calculated. The separation system was coupled via a coaxial sheath flow electrospray interface to a mass spectrometer, and the partial filling technique was used in the on-line analysis. Seven plant species belonging to five genera (Plantago, Veronica, Melampyrum, Succisa and Valeriana) were screened for the iridoid glycosides by the new method that was developed. The findings confirmed those of an earlier study on five of the iridoid glycosides. Some new iridoid glycosides were found in Plantago lanceolata, Veronica spicata and V. chamaedrys.
  • Keywords
    Iridoid glycosides
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2002
  • Journal title
    Journal of Chromatography A
  • Record number

    1518542