• Title of article

    Validation of the removal of acetylsalicylic acid: Recovery and determination of residues on various surfaces by high performance liquid chromatographic

  • Author/Authors

    Nozal، نويسنده , , Mar??a J. and Bernal، نويسنده , , José L. and Toribio، نويسنده , , Laura and Jiménez، نويسنده , , Juan J. Rios-Martin، نويسنده , , Mar??a T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    7
  • From page
    69
  • To page
    75
  • Abstract
    The validation of a procedure to clean glass, vinyl and stainless steel surfaces that have been exposed to acetylsalicylic acid during its manufacture is described. The cleaning procedure using two cotton swabs moistened with the mobile phase was validated using a wipe-test and a high-performance liquid chromatography (HPLC) method developed to determine low quantities of the acid. The HPLC method involves an octadecylsilane column at 55°C, a mixture of water–acetonitrile–orthophosphoric acid (779:220:1, v/v) as mobile phase and detection at 226 nm. Recoveries of 86%, 90% and 94% were obtained from vinyl, glass and stainless steel plates respectively. The validation gave acceptable levels of sensitivity, recovery, precision and linearity.
  • Keywords
    Acetylsalicylic acid
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2000
  • Journal title
    Journal of Chromatography A
  • Record number