    Simultaneous separation of angiotensin and endothelin peptide families by high-performance liquid chromatography: application to the specific radioimmunoassay measurement of angiotensin II or endothelin-1 from tissue

  • Author/Authors

    Naik، نويسنده , , George O.A and Moe، نويسنده , , Gordon W، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    13
  • From page
    349
  • To page
    361
  • Abstract
    Currently available measurements of endogenous angiotensin II (ANG II) and endothelin-1 (ET-1) concentrations by radioimmunoassay (RIA) lack specificity to ANG II or ET-1. ANG II and ET-1 antibodies cross-react with immuno-reactive angiotensin and endothelin family members, respectively. We have therefore developed an ion-pair reversed-phase high-performance liquid chromatography (HPLC) for simultaneously separating angiotensin and endothelin peptides and enhancing RIA specificity in the measurement of ANG II and ET-1. The developed HPLC separation was applied to canine myocardium extracts; ANG II or ET-1 fractions were collected and quantified by RIA. Elution times for both peptide families, ANG I, ANG II, ANG III, ANG IV, ANG II(4–8), bET-1, ET-1, ET-2 and ET-3 were within 25 min. In normal canine myocardium from the right atrium, right ventricle, left atrium and left ventricle, ANG II concentrations were 39±11, 28±21, 31±11 and 21±8 fmol/g and ET-1 concentrations were 43±16, 42±19, 55±21 and 57±34 fmol/g (mean±SD, N=7), respectively. The combination of HPLC with RIA renders the measurement of ANG II or ET-1 specific and convenient, and saves time. This HPLC separation may be applied to the specific measurement of other immuno-reactive angiotensin and endothelin peptides.
  • Keywords
    Peptides , Endothelins , Angiotensins
  • Journal title
    Journal of Chromatography A
  • Serial Year
    2000
  • Journal title
    Journal of Chromatography A
  • Record number

    1526851