Title of article
Design basis earthquakes for critical industrial facilities and their characteristics, and the Southern Hyogo prefecture earthquake, 17 January 1995
Author/Authors
Shibata، نويسنده , , Heki، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
13
From page
157
To page
169
Abstract
This paper deals with how to establish the concept of the design basis earthquake (DBE) for critical industrial facilities such as nuclear power plants in consideration of disasters such as the Southern Hyogo prefecture earthquake, the so-called Kobe earthquake in 1995. The author once discussed various DBEs at the 7th World Conference on Earthquake Engineering. At that time, the author assumed that the strongest effective PGA would be 0.7 G, and compared the values of accelerations of a structure obtained by various codes in Japan and other countries. The maximum PGA observed by an instrument at the Southern Hyogo prefecture earthquake in 1995 exceeded the previous assumption of the author, even though the results of the previous paper had been pessimistic. According to the experience of the Kobe event, the author will point out the necessity of the third earthquake Ss adding to S1 and S2 of previous DBEs.
Journal title
Reliability Engineering and System Safety
Serial Year
1998
Journal title
Reliability Engineering and System Safety
Record number