• Title of article

    The design and calibration of a phantom for depth profiling measurements of entrained radioactivity in silica-based media

  • Author/Authors

    Shippen، نويسنده , , B. Alan and Joyce، نويسنده , , Malcolm J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    526
  • To page
    532
  • Abstract
    The development of a phantom which replicates the effect of concrete on radioactivity entrained within it is described. The phantom was designed as a basis on which methods can be developed to measure the depth of radioactive contamination in the concrete of defunct nuclear facilities. In particular, this apparatus has been used to validate a differential attenuation method for the profiling of radioactive contamination at depth. Entrained radioactive contamination is a significant issue in defunct nuclear facilities where in situ, non-destructive assay of radioactive waste arisings is a routine requirement. antom comprises a polymethylmethacrylate structure filled with high-purity silica-sand which, for the purposes of the application, is an effective analogue of fully-hydrated concrete paste. A void was created within the silica sand which incorporates a sliding mechanism for the insertion of a radioactive source to a required depth. The sealed source represents the entrained radioactivity in the phantom but is also specifiable, removable and poses no long-term contamination risk beyond the expected life of the apparatus. The remainder of the void either side of the source is filled with silica-sand to complete the homogeneity of the phantom. The void was situated near the front of the phantom constructed at a 5.14° angle with respect to the front scanning surface; thus the apparent depth within the silica-sand can be varied by changing the position of the source along the phantomʹs void. eps taken to develop the concrete phantom are described. The design has been validated with a set of radiation transport simulations affording comparison with an exemplar of the concrete found used in nuclear facilities. Some initial results from measurements taken with the phantom and a caesium-137 γ-radiation source in combination with a sodium iodide radiation detector are provided. These measurements are used to validate the differential attenuation method and compared with data from previous measurement attempts with concrete slices.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2011
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    1590417