• Title of article

    A laser leak detector for leakage monitoring of fuel channel closure plugs in pressurized heavy water reactors

  • Author/Authors

    Park، نويسنده , , Hyunmin and Kim، نويسنده , , Taek-Soo and Lee، نويسنده , , Han-Lim and Lee، نويسنده , , Sung-Uk and Ko، نويسنده , , Kwang-Hoon and Jeong، نويسنده , , Do-Young and Kim، نويسنده , , Hyun-Taek and Kim، نويسنده , , Do-Hyung، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    880
  • To page
    885
  • Abstract
    In light of a recent development in a coolant leakage detection method for pressurized heavy water reactors (PHWRs), which utilizes a novel leak detector based on laser absorption spectroscopy, we report the successful application of the said detection method for the detection and location of leaks in the fuel channel closure plug of the PHWRs. This paper contains the results of real-world performance tests performed on operational commercial PHWRs, and shows that the newly developed laser leak detector was fully capable of finding leak locations as well as detecting leaks with a sensitivity of less than ∼1 g/h. Based on these findings, we believe the laser leak detector can be a reliable apparatus for the early detection of heavy water leakage at fuel channel closure plugs during the normal operation of PHWRs.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2013
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    1593798