Title of article
The challenging requirements of the ITER anti seismic bearings
Author/Authors
Syed، نويسنده , , M.B. and Patisson، نويسنده , , L. and Curtido، نويسنده , , M. and Slee، نويسنده , , B. and Diaz، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
5
From page
212
To page
216
Abstract
ITER is being designed and constructed with a high level of safety as an essential requirement. In order to meet the safety and performance objectives of ITER and the French regulatory requirements, the Tokamak Complex has been isolated from the potential seismic hazard by anti-seismic bearings. The dynamic characteristics of the anti-seismic bearings were chosen so that the Tokamak Complex will have a fundamental horizontal frequency of 0.55 Hz. The design, manufacturing and qualification of ASBs have been carried out by NUVIA Travaux Speciaux with specific ITER requirements that are much more stringent than the applicable European and French Norms and directives.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2014
Journal title
Nuclear Engineering and Design Eslah
Record number
1594160
Link To Document