• Title of article

    Separate effects tests to determine the effective thermal conductivity in the PBMR HTTU test facility

  • Author/Authors

    Rousseau، نويسنده , , P.G. and du Toit، نويسنده , , C.G. and van Antwerpen، نويسنده , , W. and van Antwerpen، نويسنده , , H.J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    15
  • From page
    444
  • To page
    458
  • Abstract
    Thermal-fluid simulations are used extensively to predict the maximum fuel temperatures, flows, pressure drops and thermal capacitance of pebble bed gas cooled reactors in support of the reactor safety case. The PBMR company developed the HTTU non-nuclear test facility in cooperation with M-Tech Industrial (Pty) Ltd. and the North-West University in South Africa to conduct comprehensive separate effects tests as well as integrated effects tests to study the different thermal-fluid phenomena. This paper describes the separate effects tests that were conducted to determine the effective thermal conductivity through the pebble bed under near-vacuum conditions and temperatures up to 1200 °C. It also presents the measured temperature distributions and the methodology applied in the data analysis to derive the resultant values of effective thermal conductivity and its associated uncertainty.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2014
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number