• Title of article

    Numerical and experimental assessment of thermal performance of vertical energy piles: An application

  • Author/Authors

    Gao، نويسنده , , Jun and Zhang، نويسنده , , Xu and Liu، نويسنده , , Jun and Li، نويسنده , , Kuishan and Yang، نويسنده , , Jie، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    10
  • From page
    901
  • To page
    910
  • Abstract
    A district space heating and cooling system using geothermal energy from bearing piles was designed in Shanghai and will be installed in two years before 2010. This paper describes the pile-foundation heat exchangers applied in an energy pile system for an actual architectural complex in Shanghai, 30% of whose cooling/heating load was designed to be provided by a ground-source heat pump (GSHP) system using the energy piles. In situ performance tests of heat transfer are carried out to figure out the most efficient type of energy pile and to specify the design of energy pile system. Numerical investigation is also performed to confirm the test results and to demonstrate the medium temperature variations along the pipes. The averaged heat resistance and heat injection rate of different types of energy piles are calculated from the test and numerical results. The effect of pile type, medium flow rate and inlet temperature on thermal performance is separately discussed. From the viewpoint of energy efficiency and adjustability, the W-shaped underground heat exchanger with moderate medium flow rate is finally adopted for the energy pile system.
  • Keywords
    Energy pile , Pile foundation , Thermal Performance , Geothermal energy , Ground-source heat pump
  • Journal title
    Applied Energy
  • Serial Year
    2008
  • Journal title
    Applied Energy
  • Record number

    1602594