• Title of article

    Spatial optimization of an underhood cooling module – Towards an innovative control approach

  • Author/Authors

    Khaled، نويسنده , , Mahmoud and Harambat، نويسنده , , Fabien and Hage، نويسنده , , Hicham El and Peerhossaini، نويسنده , , Hassan، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    9
  • From page
    3841
  • To page
    3849
  • Abstract
    The present paper reports a numerical investigation of spatial optimization of heat-exchanger by acting on its positioning in the vehicle’s cooling module. This analysis also elucidates how to act on the different parameters influencing heat-exchanger performance in order to optimize their functioning. A two-dimensional computation code permits optimizing the performance of the cooling module by positioning different heat exchangers, in both the driving and stop phases of the vehicle. The ultimate aim is to apply new control approaches to real vehicles so as to reduce pump and compressor energy consumption and thus fuel consumption. Compared to a reference “in-series” configuration of the cooling module HXs (in which the different HXs are superposed in the airflow direction), an “in-parallel” configuration (in which the different HX surfaces are in a row with respect to the air flow direction) increases the thermal power of the HXs by 4.4% and decreases the pressure losses by 0.9%.
  • Keywords
    Vehicle cooling module , Underhood thermal management
  • Journal title
    Applied Energy
  • Serial Year
    2011
  • Journal title
    Applied Energy
  • Record number