Title of article
Sensitivity analysis of the numerical study on the thermal performance of a packed-bed molten salt thermocline thermal storage system
Author/Authors
Xu، نويسنده , , Chao and Wang، نويسنده , , Zhifeng and He، نويسنده , , Yaling and Li، نويسنده , , Xin and Bai، نويسنده , , Fengwu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
11
From page
65
To page
75
Abstract
In this paper, a comprehensive transient, two-dimensional, two-phase model for heat transfer and fluid dynamics within the packed-bed molten salt thermocline thermal storage system is presented. After model validation, the developed model is used to investigate the general thermal behavior of a discharging process of the pack-bed thermocline system and evaluate the interstitial heat transfer coefficient, the effective thermal conductivity and effect of the thermal conductivity of solid fillers. The results show that the thermocline region is moving upward with slight expansion during the discharging process. With the use of two insulation layers, a uniform cross-sectional temperature distribution is well achieved. The use of different correlations for the interstitial heat transfer coefficient or the effective thermal conductivity from the literature leads to negligible difference in the predicted thermal performance. It is also found that decreasing the heat transfer rate between fluid and solid fillers, or increasing the thermal conductivity of solid fillers, results in an increase in the thermocline thickness which finally decreases the effective discharging time and the effective discharging efficiency.
Keywords
Numerical model , Thermocline , Packed-bed , Thermal energy storage , Molten salt
Journal title
Applied Energy
Serial Year
2012
Journal title
Applied Energy
Record number
1605212
Link To Document