Title of article
Performance of a-Si thin film PV modules with and without water flow: An experimental validation
Author/Authors
Gaur، نويسنده , , Ankita and Tiwari، نويسنده , , G.N.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
8
From page
184
To page
191
Abstract
Analytical expressions have been developed to calculate the temperature dependent electrical efficiency (ηm) and the effect of water flow on the performance of a-Si thin film photovoltaic (PV) modules. The calculated results have been validated by experimental investigations on commercially available a-Si thin film PV modules. With water flow on the PV module, ηm is observed to increase, which has been attributed to the dissipation of thermal energy associated with the PV modules due to water flow on it. The effects of mass flow rates of water ( m . w ) on module to water heat transfer coefficient (hm,w) and ηm have also been calculated. Increment in m . w , increases both the hm,w and ηm. For low m . w of 0.001 kg/s, the hm,w and ηm were calculated to be 14.2 W/m2 K and 7% respectively, whereas for high m . w of 0.85 kg/s, the hm,w and ηm were calculated to be 413 W/m2 K and 7.45% respectively. Daily average electrical efficiencies of a-Si PV module with and without water flow have been found to be 7.36% and 6.85% respectively. Overall thermal efficiency and overall exergy of PV module with water flow have been found to be 22% and 7.33% respectively.
Keywords
Mass flow rate , a-Si PV modules , Photovoltaic thermal modules
Journal title
Applied Energy
Serial Year
2014
Journal title
Applied Energy
Record number
1608159
Link To Document