• Title of article

    UV dosimeters based on neotetrazolium chloride

  • Author/Authors

    Mills، نويسنده , , Andrew and Grosshans، نويسنده , , Pauline and McFarlane، نويسنده , , Michael، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    6
  • From page
    136
  • To page
    141
  • Abstract
    A novel UV dosimeter is described comprising a tetrazolium dye, neotetrazolium chloride (NTC), dissolved in a film of polymer, polyvinyl alcohol (PVA). The dosimeter is pale yellow/colourless in the absence of UV light, and turns red upon exposure to UV light. The spectral characteristics of a typical UV dosimeter film and the mechanism through which the colour change occurs are detailed. The NTC UV dosimeter films exhibit a response to UV light that is related to the intensity and duration of UV exposure, the level of dye present in the films and the thickness of the films themselves. The response of the dosimeter is temperature independent over the range 20–40 °C and, like most UV dosimeters, exhibits a cosine-like response dependence upon irradiance angle. The introduction of a layer of a UV-screening compound which slows the rate at which the dosimeter responds to UVR enables the dosimeter response to be tailored to different UV doses. The possible use of these novel dosimeters to measure solar UV exposure dose is discussed.
  • Keywords
    UV dosimeter , UV index , MED , Tetrazolium
  • Journal title
    Journal of Photochemistry and Photobiology:A:Chemistry
  • Serial Year
    2009
  • Journal title
    Journal of Photochemistry and Photobiology:A:Chemistry
  • Record number