Title of article
Implementation of self-consolidating concrete in caisson construction for the Stalnaker Run Bridge
Author/Authors
Sweet، نويسنده , , Joseph G. and Chen، نويسنده , , Hung-Liang (Roger)، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
9
From page
545
To page
553
Abstract
To utilize cast-in-place self-consolidating concrete (SCC) for caissons on a rural bridge replacement, specifications were first written as guidelines. A mix design was developed and tested in a reusable trial caisson that would simulate field casting conditions. A fresh sampling technique was devised to investigate the distribution of SCC within the trial caisson. Petrographic analysis of hardened samples was done to quantify the amounts of aggregates present at twenty different locations within the trial caisson. The SCC mix design was then successfully used to cast caissons of one of the two bridge abutments, with no major defects detected by cross-hole sonic logging (CSL). Hardened property tests revealed SCC compressive strengths and modulus of elasticity values that were similar to a traditional caisson concrete used on the project, while the total measured shrinkage and the splitting tensile strengths of the field SCC were seen to be lower than those of the traditional caisson concrete.
Keywords
Tremie placement , sampling , self-consolidating concrete , drilled shaft , Cast-in-place concrete , Caisson , petrography , Aggregate distribution
Journal title
Construction and Building Materials
Serial Year
2012
Journal title
Construction and Building Materials
Record number
1633462
Link To Document