• Title of article

    Behavior of welded CFT column to H-beam connections with external stiffeners

  • Author/Authors

    Shin، نويسنده , , Kyung-Jae and Kim، نويسنده , , Young-Ju and Oh، نويسنده , , Young-Suk and Moon، نويسنده , , Tae-Sup، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    11
  • From page
    1877
  • To page
    1887
  • Abstract
    This paper focuses on the experimental and analytical behavior of concrete filled tubular (CFT) column to H-beam welded moment connections with external T-stiffeners. Six full-scale specimens were tested cyclically. All specimens were designed and manufactured using the following main test parameters: (a) the strength ratio of the horizontal stiffener to the beam flange; and (b) the strength ratio of the vertical stiffener to the beam flange. Three types of failure modes, horizontal stiffeners failure, vertical stiffener failure and beam failure, were obtained. The connections reinforced with T-stiffeners having 130% of strength to beam flanges showed stable hysteretic behavior and good ductility. The ABAQUS finite element package was used to simulate the experimental behavior. The results obtained from the finite element were evaluated by comparing the load–displacement responses and the potential of failure modes.
  • Keywords
    Concrete filled tube (CFT) , T-stiffener , Moment-resisting frame , Plastic rotation
  • Journal title
    Engineering Structures
  • Serial Year
    2004
  • Journal title
    Engineering Structures
  • Record number