• Title of article

    Thermal and stress analysis of Kinta RCC dam

  • Author/Authors

    Noorzaei، نويسنده , , J. and Bayagoob، نويسنده , , K.H. and Thanoon، نويسنده , , W.A. and Jaafar، نويسنده , , M.S.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    8
  • From page
    1795
  • To page
    1802
  • Abstract
    The thermal analysis of roller compacted concrete dams (RCC) plays an important role in their design and construction. This paper focuses on the application and verification of a two-dimensional finite element code developed for the thermal and structural analysis of RCC dams. The Kinta RCC gravity dam, which is the first RCC dam in Malaysia, has been taken for the purpose of verification of the finite element code. The dam is 78 m in height and still under construction. The actual climatic conditions and thermal properties of the materials were considered in the analysis. The predicted temperatures obtained from the finite element code that was developed are found to be in good agreement with actual temperatures measured in the field using thermocouples installed within the dam body.
  • Keywords
    Roller compacted concrete dams , Birth death , thermal analysis , Placing temperature , Finite element