• Title of article

    Parametric analysis of a steam cycle with a quasi-isothermal expansion

  • Author/Authors

    S. P. Cicconardi، نويسنده , , S.P. and Jannelli، نويسنده , , E. and Perna، نويسنده , , A. and Spazzafumo، نويسنده , , G.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    5
  • From page
    275
  • To page
    279
  • Abstract
    Using a hydrogen/oxygen steam generator it is possible to carry out many steam mixing re-heatings without increasing the complexity of a traditional steam power-plant: steam is not required to re-enter the boiler for each re-heating. An isothermal expansion could thus be approached by means of several adiabatic expansions and several steam mixing re-heatings. A theoretical investigation showed that an isothermal expansion could achieve high efficiency (up to 70% of HHV) when the waste heat at the turbine outlet is recovered for pre-heating water, hydrogen and oxygen. In a real plant the number of re-heatings that can be carried out, although high, is limited and we can therefore expect an efficiency drop which varies as a function of the number of re-heatings, the re-heating temperature and the maximum pressure. In order to evaluate real cycle performance, a numerical code, specifically created, was implemented.
  • Journal title
    International Journal of Hydrogen Energy
  • Serial Year
    2001
  • Journal title
    International Journal of Hydrogen Energy
  • Record number

    1648555